Automatic Door Activation & Safety for Standard and Escape Route Doors
Dual Technology – 3.5m mounting height
Installation height 3.5m / 11.5ft Max
Supply voltage AC: 12- 24V DC: 12 - 30V ±10% 50/60Hz
Power consumption AC12V - 2.4VA max AC24V - 2.5VA max
DC12V - 150mA max DC30V - 80mA max
Infrared (safety output) Opto Relay Non Pole
Voltage: 48 VDC max Current: 300 mA max (resistance load)
Radar - Activation Output 1 Contact Output: Opto Relay Non Pole
Voltage: 48 VDC max Current: 300 mA max (resistance load)
Pulse Output: Opto Relay Non Pole
Voltage: 48 VDC max Current: 300 mA max (resistance load)
Output frequency 100Hz duty 1:1
Radar - Activation Output 2 Output voltage: Min 3.2 VDC at 10mA
Open circuit voltage: max 7 VDC
Test input 6mA max at 30 VDC
Operating temperature -20 to +60°C, (-4 t0 140°F)
Operating humidity Below 80%
IP rating IP54
Category Cat 2/PL.d (IR), Cat 2/PL.d (radar) according to EN ISO 13849-1:2015
Brand | Hotron |
---|---|
Installation Method | Wall Mounted |
Catalogue Text | Automatic Door Activation & Safety |